Computerized Two-dimensional Cervical And Lumbar Traction Bed
Classification:
Product Introduction
Product Introduction
1. Power supply voltage: 220V ± 22V, 50Hz ± 1Hz
2. Rated input power: 100 ~ 240VA
3. Lumbar traction stroke: 0-200mm
4. Lumbar traction total time: 0-60min any adjustable
5. Lumbar traction: 0-999N arbitrary adjustable
6. Continuous traction time: 0-9min arbitrary adjustable
7. Intermittent traction time: 0-9min arbitrary adjustable
8. Microcomputer control lumbar traction
9. Intelligent digital display time, traction
10. Traction force automatic compensation function, over force protection system.
11. Simple traction parameter input method
12. Traction system: It is a combination of technical personnel and clinical research and development of medical experts. The system is a multifunctional lumbar traction bed, and the software is equipped with case file management. All kinds of parameters are controlled by computer. The whole process is monitored by microcomputer for lumbar traction, traction time, intermittent time, repeated traction frequency, machine working state and other technical parameters. The operator clearly grasps the situation of traction system for the treatment of patients.
13. Scope of adaptation: lumbar disc herniation, degeneration disorder, dislocation and dislocation, thoracolumbar compression fracture (without paraplegia), change of lumbar physiological arc disappearance or posterior process, lumbar scoliosis.
14. Contraindications: spinal tuberculosis, tumor, severe heart disease, severe diabetes, fracture osteoporosis, skin lesions or fractures in traction area, pregnant women, etc.
Product Introduction
The traction system is developed by a combination of technical personnel and medical experts. The system is a multifunctional lumbar traction bed, and the software is equipped with case file management. Four-dimensional traction bed has computer control, three-dimensional traction bed has microcomputer control. In the whole process, the computer monitors the technical parameters such as cervical and lumbar traction, angular angle, rotation angle, traction time, intermittent time, repeated traction frequency, machine working state, etc., and the operator clearly grasps the traction system's treatment state of the patient. The bed can correct the lesions in the three-dimensional direction between the vertebral bodies and restore the physiological curvature of the spine. The four-dimensional three-dimensional alternate traction that cannot be achieved by manual methods is realized. Is the real realization of the computer application, mechatronics products. In the low temperature area optional heating device, can relieve pain, relax muscles and ligaments, promote blood circulation, improve the treatment effect.
Scope of application
Lumbar disc herniation, degenerative disorder, dislocation and dislocation, thoracolumbar compression fracture (without paraplegia), change of lumbar physiological curvature or posterior process, lumbar scoliosis. Cervical spine: traumatic neck fracture, dislocation or dislocation, cervical spondylosis caused by dizziness, headache, abnormal blood pressure, vision and language disorders and other symptoms.
Contraindications
Spinal tuberculosis, tumor, severe heart disease, severe diabetes, osteoporosis, traction area skin lesions or fractures, pregnant women, etc.
Key words:
Computerized two-dimensional cervical and lumbar traction bed
Online message
Leave a message online and get the product quotation free of charge. We will arrange the specialist to contact you as soon as possible.